INTRODUCTION
These are 6 tools to help in fluid flow simulation.1- Pressure Drop (dP) Calculator
Given Flow, Density, Diameter, K fitting
Flow Rate (Kg/hr): | |
Density (kg/m3): | |
Inside Diameter (mm): | |
K fitting: | |
Pressure Drop (bar): |
2- K Fitting Calculator
Given Flow, Density, Diameter, Pressure Drop
Flow Rate (Kg/hr): | |
Density (kg/m3): | |
Inside Diameter (mm): | |
Pressure Drop (bar): | |
K fitting: |
3- Flow (F) Calculator
Given Density, Diameter, Pressure Drop, K Fitting
Density (kg/m3): | |
Inside Diameter (mm): | |
Pressure Drop (bar): | |
K fitting: | |
Flow Rate (Kg/hr): |
4- Cv to K & Kv Converter
Inside Diameter (mm): | |
Flow Coefficient (Cv): | |
Resistance coefficient (K): | |
Resistance coefficient (Kv): |
5- K to Cv & Kv Converter
Inside Diameter (mm): | |
Resistance Coefficient (K): | |
Flow coefficient (Cv): | |
Resistance coefficient (Kv): |
6- Kv to Cv & K Converter
Inside Diameter (mm): | |
Flow Coefficient (Kv): | |
Flow coefficient (Cv): | |
Resistance coefficient (K): |
Friction Loss Tables
Source:- https://www.plumbingsupply.com/ed-frictionlosses.htmlFriction Losses in
Pipe Fittings Resistance Coefficient K (use in formula hf = Kv2/2g) |
||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Fitting | LD | Nominal Pipe Size | ||||||||||||
1/2" | 3/4" | 1 | 1-1/4" | 1-1/2" | 2 | 2-1/2"-3 | 4 | 6 | 8-10 | 12-16 | 18-24 | |||
K Value | ||||||||||||||
Angle Valve | 55 | 1.48 | 1.38 | 1.27 | 1.21 | 1.16 | 1.05 | 0.99 | 0.94 | 0.83 | 0.77 | 0.72 | 0.66 | |
Angle Valve | 150 | 4.05 | 3.75 | 3.45 | 3.30 | 3.15 | 2.85 | 2.70 | 2.55 | 2.25 | 2.10 | 1.95 | 1.80 | |
Ball Valve | 3 | 0.08 | 0.08 | 0.07 | 0.07 | 0.06 | 0.06 | 0.05 | 0.05 | 0.05 | 0.04 | 0.04 | 0.04 | |
Butterfly Valve | 0.86 | 0.81 | 0.77 | 0.68 | 0.63 | 0.35 | 0.30 | |||||||
Gate Valve | 8 | 0.22 | 0.20 | 0.18 | 0.18 | 0.15 | 0.15 | 0.14 | 0.14 | 0.12 | 0.11 | 0.10 | 0.10 | |
Globe Valve | 340 | 9.2 | 8.5 | 7.8 | 7.5 | 7.1 | 6.5 | 6.1 | 5.8 | 5.1 | 4.8 | 4.4 | 4.1 | |
Plug Valve Branch Flow | 90 | 2.43 | 2.25 | 2.07 | 1.98 | 1.89 | 1.71 | 1.62 | 1.53 | 1.35 | 1.26 | 1.17 | 1.08 | |
Plug Valve Straightaway | 18 | 0.48 | 0.45 | 0.41 | 0.40 | 0.38 | 0.34 | 0.32 | 0.31 | 0.27 | 0.25 | 0.23 | 0.22 | |
Plug Valve 3-Way Thru-Flow | 30 | 0.81 | 0.75 | 0.69 | 0.66 | 0.63 | 0.57 | 0.54 | 0.51 | 0.45 | 0.42 | 0.39 | 0.36 | |
Standard Elbow | 90° | 30 | 0.81 | 0.75 | 0.69 | 0.66 | 0.63 | 0.57 | 0.54 | 0.51 | 0.45 | 0.42 | 0.39 | 0.36 |
45° | 16 | 0.43 | 0.40 | 0.37 | 0.35 | 0.34 | 0.30 | 0.29 | 0.27 | 0.24 | 0.22 | 0.21 | 0.19 | |
long radius 90° |
16 | 0.43 | 0.40 | 0.37 | 0.35 | 0.34 | 0.30 | 0.29 | 0.27 | 0.24 | 0.22 | 0.21 | 0.19 | |
Close Return Bend | 50 | 1.35 | 1.25 | 1.15 | 1.10 | 1.05 | 0.95 | 0.90 | 0.85 | 0.75 | 0.70 | 0.65 | 0.60 | |
Standard Tee | Thru-Flow | 20 | 0.54 | 0.50 | 0.46 | 0.44 | 0.42 | 0.38 | 0.36 | 0.34 | 0.30 | 0.28 | 0.26 | 0.24 |
Thru-Branch | 60 | 1.62 | 1.50 | 1.38 | 1.32 | 1.26 | 1.14 | 1.08 | 1.02 | 0.90 | 0.84 | 0.78 | 0.72 | |
90 Bends, Pipe Bends, Flanged Elbows, Butt-Welded Elbows |
r/d=1 | 20 | 0.54 | 0.50 | 0.46 | 0.44 | 0.42 | 0.38 | 0.36 | 0.34 | 0.30 | 0.28 | 0.26 | 0.24 |
r/d=2 | 12 | 0.32 | 0.30 | 0.28 | 0.26 | 0.25 | 0.23 | 0.22 | 0.20 | 0.18 | 0.17 | 0.16 | 0.14 | |
r/d=3 | 12 | 0.32 | 0.30 | 0.28 | 0.26 | 0.25 | 0.23 | 0.22 | 0.20 | 0.18 | 0.17 | 0.16 | 0.14 | |
r/d=4 | 14 | 0.38 | 0.35 | 0.32 | 0.31 | 0.29 | 0.27 | 0.25 | 0.24 | 0.21 | 0.20 | 0.18 | 0.17 | |
r/d=6 | 17 | 0.46 | 0.43 | 0.39 | 0.37 | 0.36 | 0.32 | 0.31 | 0.29 | 0.26 | 0.24 | 0.22 | 0.20 | |
r/d=8 | 24 | 0.65 | 0.60 | 0.55 | 0.53 | 0.50 | 0.46 | 0.43 | 0.41 | 0.36 | 0.34 | 0.31 | 0.29 | |
r/d=10 | 30 | 0.81 | 0.75 | 0.69 | 0.66 | 0.63 | 0.57 | 0.54 | 0.51 | 0.45 | 0.42 | 0.39 | 0.36 | |
r/d=12 | 34 | 0.92 | 0.85 | 0.78 | 0.75 | 0.71 | 0.65 | 0.61 | 0.58 | 0.51 | 0.48 | 0.44 | 0.41 | |
r/d=14 | 38 | 1.03 | 0.95 | 0.87 | 0.84 | 0.80 | 0.72 | 0.68 | 0.65 | 0.57 | 0.53 | 0.49 | 0.46 | |
r/d=16 | 42 | 1.13 | 1.05 | 0.97 | 0.92 | 0.88 | 0.80 | 0.76 | 0.71 | 0.63 | 0.59 | 0.55 | 0.50 | |
r/d=18 | 45 | 1.24 | 1.15 | 1.06 | 1.01 | 0.97 | 0.87 | 0.83 | 0.78 | 0.69 | 0.64 | 0.60 | 0.55 | |
r/d=20 | 50 | 1.35 | 1.25 | 1.15 | 1.10 | 1.05 | 0.95 | 0.90 | 0.85 | 0.75 | 0.70 | 0.65 | 0.60 | |
Mitre Bends | a=0° | 2 | 0.05 | 0.05 | 0.05 | 0.04 | 0.04 | 0.04 | 0.04 | 0.03 | 0.03 | 0.03 | 0.03 | 0.02 |
a=15° | 4 | 0.11 | 0.10 | 0.09 | 0.09 | 0.08 | 0.08 | 0.07 | 0.07 | 0.06 | 0.06 | 0.05 | 0.05 | |
a=30° | 8 | 0.22 | 0.20 | 0.18 | 0.18 | 0.17 | 0.15 | 0.14 | 0.14 | 0.12 | 0.11 | 0.10 | 0.10 | |
a=45° | 15 | 0.41 | 0.38 | 0.35 | 0.33 | 0.32 | 0.29 | 0.27 | 0.26 | 0.23 | 0.21 | 0.20 | 0.18 | |
a=60° | 25 | 0.68 | 0.63 | 0.58 | 0.55 | 0.53 | 0.48 | 0.45 | 0.43 | 0.38 | 0.35 | 0.33 | 0.30 | |
a=75° | 40 | 1.09 | 1.00 | 0.92 | 0.88 | 0.84 | 0.76 | 0.72 | 0.68 | 0.60 | 0.56 | 0.52 | 0.48 | |
a=90° | 60 | 1.62 | 1.50 | 1.38 | 1.32 | 1.26 | 1.14 | 1.08 | 1.02 | 0.90 | 0.84 | 0.78 | 0.72 | |
Note: Fittings are standard with full openings. |
Fitting | L/D | Minimum Velocity for Full Disc Lift |
Nominal Pipe Size | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
1/2" | 3/4" | 1 | 1-1/4" | 1-1/2" | 2 | 2-1/2"-3 | 4 | 6 | 8-10 | 12-16 | 18-24 | ||||
General ft/sec |
Water ft/sec |
K Value | |||||||||||||
Swing Check Valve | 100 | 35 | 4.40 | 2.70 | 2.50 | 2.30 | 2.20 | 2.10 | 1.90 | 1.80 | 1.70 | 1.50 | 1.40 | 1.30 | 1.20 |
50 | 48 | 6.06 | 1.40 | 1.30 | 1.20 | 1.10 | 1.10 | 1.00 | 0.90 | 0.90 | 0.75 | 0.70 | 0.65 | 0.60 | |
Lift Check Valve | 600 | 40 | 5.06 | 16.2 | 15.0 | 13.08 | 13.2 | 12.6 | 11.4 | 10.8 | 10.2 | 9.0 | 8.4 | 7.8 | 7.2 |
55 | 140 | 17.7 | 1.50 | 1.40 | 1.30 | 1.20 | 1.20 | 1.10 | 1.00 | 0.94 | 0.83 | 0.77 | 0.72 | 0.66 | |
Tilting Disc Check Valve | 5 | 80 | 10.13 | 0.76 | 0.72 | 0.68 | 0.60 | 0.56 | 0.39 | 0.24 | |||||
15 | 30 | 3.80 | 2.30 | 2.20 | 2.00 | 1.80 | 1.70 | 1.20 | 0.72 | ||||||
Foot Valve with Strainer Poppet Disc |
420 | 15 | 1.90 | 11.3 | 10.5 | 9.70 | 9.30 | 8.80 | 8.00 | 7.60 | 7.10 | 6.30 | 5.90 | 5.50 | 5.0 |
Foot Valve with Strainer Hinged Disc |
75 | 35 | 4.43 | 2.00 | 1.90 | 1.70 | 1.70 | 1.70 | 1.40 | 1.40 | 1.30 | 1.10 | 1.10 | 1.00 | 0.90 |
Fitting | Description | All Pipe Sizes |
---|---|---|
K Value | ||
Pipe Exit | Projecting Sharp-Edged Rounded |
1.00 |
Pipe Entrance | Inward Projecting | 0.78 |
Pipe Entrance Flush | Sharp-Edged | 0.50 |
r/d=0.02 | 0.28 | |
r/d=0.04 | 0.24 | |
r/d=0.06 | 0.15 | |
r/d=0.10 | 0.09 | |
r/d<0.14 | 0.04 |
The K values given below are for making estimates of friction loss in cases not covered in the previous tables.
Type of Fitting | K Value | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Disk or Wobble Meter | 3.4 - 10 | ||||||||||
Rotary Meter (Star or Cog-Wheel Piston) | 10 | ||||||||||
Reciprocating Piston Meter | 15 | ||||||||||
Turbine Wheel (Double-Flow) Meter | 5 - 7.5 | ||||||||||
Bends w/Corrugated Inner Radius | 1.3 - 1.6 times value for smooth bend | ||||||||||
Example: Determine L
(friction loss in pipe fittings in terms of equivalent length in feet of straight pipe). Assume a 6" angle valve for Schedule 40 pipe size. Select the appropriate K value for such and select D and f for Schedule 40 pipe from the table below where K is the pipe diameter in feet. |
|||||||||||
Pipe Size Inches Sch. 40 |
D feet |
f | Pipe Size Inches Sch. 40 |
D feet |
f | Pipe Size Inches Sch. 40 |
D feet |
f | Pipe Size Inches Sch. 40 |
D feet |
f |
1/2" 3/4" 1 1-1/4" 1-1/2" 2 |
0.0518 0.0687 0.0874 0.1150 0.1342 0.1723 |
0.027 0.025 0.023 0.022 0.021 0.019 |
2-1/2" 3 4 5 6 8 |
0.2058 0.2557 0.3355 0.4206 0.5054 0.6651 |
0.018 0.018 0.017 0.016 0.015 0.014 |
10 12 14 16 18 20 |
0.8350 0.9948 1.0937 1.250 1.4063 1.5678 |
0.014 0.013 0.013 0.013 0.012 0.012 |
24 30 36 42 48 |
1.8857 2.3333 2.8333 3.3333 3.8333 |
0.012 0.011 0.011 0.010 0.010 |
Friction Loss of Water in
Pipe Fittings in Terms of Equivalent Length - Feet of Straight Pipe |
||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Nominal pipe size |
Actual inside diameter inches d |
Friction factor f |
Gate valve - full open |
90° elbow |
Long radius 90° or 45° sth elbow |
Sth tee - thru flow |
Sth tee - branch flow |
Close return bend |
Swing check valve - full open |
Angle valve - full open |
Globe valve - full valve |
Butter- fly valve |
90°Welding elbow |
Mitre bend | ||
r/d = 1 | r/d = 2 | 45° | 90° | |||||||||||||
1/2" 3/4" 1 1-1/4" 1-1/2" |
.622 .824 1.049 1.380 1.610 |
.027 .025 .023 .022 .021 |
.41 .55 .70 .92 1.07 |
1.55 2.06 2.62 3.45 4.03 |
.83 1.10 1.40 1.84 2.15 |
1.04 1.37 1.75 2.30 2.68 |
3.11 4.12 5.25 6.90 8.05 |
2.59 3.43 4.37 5.75 6.71 |
5.18 6.86 8.74 11.5 13.4 |
7.78 10.3 13.1 17.3 20.1 |
17.6 23.3 29.7 39.1 45.6 |
|||||
2 2-1/2" 3 4 5 |
2.067 2.469 3.068 4.026 5.047 |
.019 .018 .018 .017 .016 |
1.38 1.65 2.04 2.68 3.36 |
5.17 6.17 7.67 10.1 12.6 |
2.76 3.29 4.09 5.37 6.73 |
3.45 4.12 5.11 6.71 8.41 |
10.3 12.3 15.3 20.1 25.2 |
8.61 10.3 12.8 16.8 21.0 |
17.2 20.6 25.5 33.6 42.1 |
25.8 30.9 38.4 50.3 63.1 |
58.6 70.0 86.9 114 143 |
7.75 9.26 11.5 15.1 18.9 |
3.45 4.12 5.11 6.71 8.41 |
2.07 2.47 3.07 4.03 5.05 |
2.58 3.08 3.84 5.03 6.31 |
10.3 12.3 15.3 20.1 25.2 |
6 8 10 12 14 |
6.065 7.981 10.02 11.938 13.124 |
.015 .014 .014 .013 .013 |
4.04 5.32 6.68 7.96 8.75 |
15.2 20.0 25.1 29.8 32.8 |
8.09 10.6 13.4 15.9 17.5 |
10.1 13.3 16.7 19.9 21.8 |
30.3 39.9 50.1 59.7 65.6 |
25.3 33.3 41.8 49.7 54.7 |
50.5 33.3 41.8 49.7 54.7 |
75.8 99.8 125 149 164 |
172 226 284 338 372 |
22.7 29.9 29.2 34.8 38.3 |
10.1 13.3 16.7 19.9 21.8 |
6.07 7.98 10.0 11.9 13.1 |
7.58 9.98 12.5 14.9 16.4 |
30.3 39.9 50.1 59.7 65.6 |
16 18 20 24 30 |
15.00 16.876 18.814 22.628 28 |
.013 .012 .012 0.12 .011 |
10.0 16.9 12.5 15.1 18.7 |
37.5 42.2 47.0 56.6 70 |
20.0 22.5 25.1 30.2 37.3 |
25.0 28.1 31.4 37.7 46.7 |
75.0 84.4 94.1 113 140 |
62.5 70.3 78.4 94.3 117 |
62.5 70.3 78.4 94.3 |
188 210 235 283 |
425 478 533 641 |
31.3 35.2 39.2 47.1 |
25.0 28.1 31.4 37.7 46.7 |
15.0 16.9 18.8 22.6 28 |
18.8 21.1 23.5 28.3 35 |
75.0 84.4 94.1 113 140 |
36 42 48 |
34 40 46 |
.011 .010 .010 |
22.7 26.7 30.7 |
85 100 115 |
45.3 53.3 61.3 |
56.7 66.7 76.7 |
170 200 230 |
142 167 192 |
56.7 66.7 76.7 |
34 40 46 |
43 50 58 |
170 200 230 |
||||
L/D | 8 | 30 | 16 | 20 | 60 | 50 | 1/2" to 6 = 100 24 to 48 =50 |
150 | 340 | 20 | 12 | 15 | 60 |
2 comments to “Flow, Pressure Drop, K, Cv, Kv Converters”
You can leave a reply or Trackback this post.
Mohmedfarhan Sheikh - August 11, 2023 at 4:26 am
NA
online youtube video downloader - September 1, 2024 at 9:37 pm
Your blog is a testament to your dedication to your craft. Your commitment to excellence is evident in every aspect of your writing. Thank you for being such a positive influence in the online community.